Хэрэв төвөөс зугтах насосны хөндийгөөс ангижрах нь өдөр тутмын үйл ажиллагааны явцад чичиргээ, чимээ шуугиан үүсгэж, заримдаа бид ажиллахаа болих шаардлагатай болдог. Тиймээс бид төвөөс зугтах шахуургын хөндийд ямар шалтгаанууд хүргэж болохыг олж мэдэх хэрэгтэй бөгөөд ингэснээр бид эдгээр асуултаас маш ухаалаг зайлсхийх боломжтой болно.
The cavitation of centrifugal pumps, or the cavitation , is a process for flow liquid bubbles and then burst. When the absolute speed of flow liquid increase, as the static pressure of flow liquid decrease, for certain particle at a certain temperature of the fluid , although there is no heat from external input, but they have reached the vapor pressure, so that particle vaporization, and the bubble generated. Along the flow path.
Хэрэв шингэний статик даралтыг уурын даралтын хэмжээнээс давсан бол хөөс маш хурдан хагарах болно. Конденсацийн тэсрэлтийн нөлөөллийн асар том хэсэг. Хэрэв бөмбөлөг нь шингэний урсгалд биш, харин чиглүүлэгч угсралтын хэсгүүдийн хананд хагарвал хөндий нь нойтон хэсгүүдэд элэгдэлд өртөх болно.
Төвөөс зугтах насос нь кавитацийн нөхцөлд ажиллахад нойтон хэсгүүдийн элэгдэл байхгүй байсан ч энэ үед төвөөс зугтах насосны дуу чимээ маш их болж, чичиргээ эрчимжиж, үр ашиг буурч, толгой нь маш бага болж байгааг олж мэдэх боломжтой.
The equipment NPSHa , also called as effective NPSH. The equipment is provided by suction equipment, in the suction position of centrifugal pump, unit weight of the liquid have surplus energy more than vaporization pressure and head . Overseas call this an effective net positive suction head, That pump inlet (head position is zero) with a full head of liquid minus vaporization pressure and the net surplus value, represented by NPSHa. Its value and parameters related to liquid properties. Because inhalation device is proportional to the square of the flow and hydraulic loss. So NPSH decreases with the increase in capacity. NPSH-Q is a decreasing curve. The NPSH have relationship with the flow condition of pumps, it was balance pump inlet pressure drop decided by centrifugal pump itself. That is to say, in order to avoid the cavitation for the pump, we require that there is extra energy that could exceed vapor pressure head in the pump inlet. Overseas call this a required net positive suction head. The physical meaning of the pump NPSH indicates the degree of pump inlet pressure drop of the liquid. The so-called net positive suction head required, It is to require the inhalation device must be provided such a large net positive suction head, in order to compensate the pressure drops, to ensure that the pump cavitation does not occur.
Олон шатлалт төвөөс зугтах насосны NPSH нь төхөөрөмжийн параметрүүдтэй ямар ч холбоогүй юм. Зөвхөн насосны оролт дахь хөдөлгөөний параметрүүдтэй холбоотой. Тодорхой хурдтай хөдөлгөөний параметрүүд ба урсгалын параметрүүдийг геометрээр тодорхойлно. Өөрөөр хэлбэл, NPSH-ийг насос өөрөө тодорхойлдог. Өгөгдсөн шахуургын хувьд шингэнээс үл хамааран тодорхой хурдтай ба насосны оролтоор урсдаг тул ижил хурдны улмаас ижил даралтын уналт, ижил NPSHr байна. Тиймээс NPSHr нь шингэний шинж чанартай ямар ч холбоогүй юм. NPSH бага байх тусам даралт бага байх болно.
Ti нь тоног төхөөрөмж нь жижиг NPSHa, дараа нь насосны хөндийд илүү сайн эсэргүүцэлтэй байх ёстой.